Installing the 100W-R and 100WP-R Endpoints
TDC-0951-001 100W-R and 100WP-R Datalogging Water Endpoint Installation Guide 14
Proprietary and Confidential
Pipe Mount Installation
The endpoint can mount on a pipe vertically, diagonally, or horizontally using a Pipe Mounting Kit and
Remote Mount Kit (see 100W-R and 100WP-R Accessories on page 10).
To mount the adapter plate on a vertical pipe
1. Take the pipe bracket and band clamp from the Pipe Mount Kit.
2. Loosen the clamp screw until the end of the band releases.
3. Push the end of the band through the hole in the pipe bracket.
4. Place the band clamp around the pipe. Push the end of the band through the hole in the band clamp and
into the entrance to the screw assembly. Tighten the band clamp until you can push the end of the band
into the hole in the pipe bracket.