User's Manual

TDC-0951-001 100W-R and 100WP-R Datalogging Water Endpoint Installation Guide 3
Proprietary and Confidential
The 100W-R and 100WP-R are high-power radio frequency automatic meter reading (AMR) devices that
attach to water registers to collect consumption usage and tamper data that the endpoint transmits to a data
collection device. The endpoint operates in both bubble-up mode and two-way modes.
The 100W-R and 100WP-R ship in Factory Mode. The endpoints acquire and transmit meter register data
within one hour following register connection. The endpoint transfers meter data immediately if the unit is
initialized with a handheld computer during installation (see Connecting, Initializing, and Programming on
page 7).
Caution Failure to initialize the endpoint may delay the initial reading up to 1 hour. The 100WP-R
endpoint will default to a consumption value of 0 if the endpoint is not programmed with Itron's
Field Deployment Manager (FDM).
The 100W-R and 100WP-R support protocols for a variety of meter manufacturer's registers. Refer to the
Water Meter Compatibility List (PUB-0063-002), for the list of supported meters and registers.
100W-R and 100WP-Rs feature the following capabilities:
Leak Detection and Reverse Flow Detection. 100W endpoints feature the same robust features as Itron's
60 series water endpoints to provide Leak Detection and Reverse Flow Detection. For more information
about Leak Detection and Reverse Flow Detection, see the Itron white paper Detecting Leaks and Reverse
Flow with 60 Series Endpoints (https://extranet-
kc.itron.com/Water%20Endpoints/Detecting%20Leaks%20and%20Reverse%20Flow%20with%2060%20
Series%20Endpoints.pdf).
Note The 100WP-R endpoint will not report reverse flow. Incremental encoded registers do
not provide a distinguishing signal while flowing in reverse.
Communication Error Indicators.
Last Good Read. The cable is cut.
Note Last Good Read may be an indicator of a damaged register.
Extended Cut Cable. The Last Good Read flag was set in the last 24 hours (FN mode) or the last 40
days (Mobile Mode).
100W-R and 100WP-R Models
100W Remote Endpoint Description
Itron Part Number
100W-R Encoder Remote, 10-inch flying lead
ERW-1300-113
100W-R Encoder Remote with Leak Sensor, 10-inch flying lead
ERW-1300-114
100WP-R Pulser Remote, 10-inch flying lead
ERW-1300-115
100WP-R Pulser Remote with Leak Sensor, 10-inch flying lead
ERW-1300-116
C H A P T E R 2
About the 100W-R and 100WP-R Endpoints