User's Manual

About the 100W-R and 100WP-R Endpoints
TDC-0951-001 100W-R and 100WP-R Datalogging Water Endpoint Installation Guide 5
Proprietary and Confidential
2. Run Mode
100W-R endpoint’s normal operation mode.
The 100W-R endpoint transmitted message is dependent on its factory settings for standard
consumption messages (SCM) or network interval message (NIM).
For SCM, the 100W default bubble-up rate is 9 seconds.
For NIM, the 100W default bubble-up rate is 6 minutes. When the endpoint is set for NIM, the
100W-R transmits a contingency SCM message every minute. Program FN mode with a
programming device to configure NIM mode.
100WP-R Operating Modes
The 100WP-R endpoint has three standard operating modes.
1. Factory Mode
100WP-R endpoints ship from the factory in Factory Mode.
The endpoint's transmitter is off.
The endpoint's receiver bubbles-up to listen for a programming command.
100WP-R endpoint encoder models attempt to read the register every hour.
Last good read and cut tamper flags may be set when a register is not connected.
If the 100WP-R reads a connected register, the endpoint automatically moves to Run Mode and defaults to
a zero consumption.
2. Run Mode
100WP-R endpoint’s normal operation mode.
The 100W transmitted message is dependent on its factory settings for standard consumption messages
(SCM) or network interval message (NIM).
For SCM, the 100WP-R default bubble-up rate is 9 seconds.
For NIM, the 100WP-R default bubble-up rate is 6 minutes. When the endpoint is set for NIM, the
100WP-R transmits a contingency SCM message every minute. NIM mode is configured by
programming NIM mode with a programming device.