User's Manual

Chapter 3 Sensus Meter Installation
22 2.4GZ OpenWay Gas Module Installation Guide
For mounting 2.4GZ OpenWay Gas Module assemblies on meters:
Use 10 - 24 x5/8-inch slotted, Fillister head screws.
For mounting indexes on 2.4GZ OpenWay Gas Module backplates:
Use 6 - 32 x 5/8-inch slotted, round head screws.
Preinstallation Preparations
Before installing the 2.4GZ OpenWay Gas Module on a meter, verify that:
All OpenWay Gas Modules are type 2.4GZ modules for your brand of gas meters.
The model numbers of all meters on which the OpenWay Gas Modules will be
installed are included in the Meter Compatibility List on page 2.
Installing the 2.4 GHz OpenWay Gas Module on a Sensus
Meter
There are four major steps to installing the 2.4GZ OpenWay Gas Module on a meter:
Remove the Existing Index
Assemble the OpenWay Gas Module
Program the OpenWay Gas Module
Attach the OpenWay Gas Module to the meter
These procedures are described in the following sections.
NOTE Be sure to properly dispose of all unused screws, old index covers,
gaskets, and other left-over materials. Do not leave any materials on customer
premises.
Remove the Existing Index
The first major step when installing a 2.4GZ OpenWay Gas Module on a Sensus meter is to
remove the existing index from the meter.
To Remove the Existing Index
1. Remove any tamper seals from the meter.