2.4GZ OpenWay Gas Module Installation Guide 27
To Program the OpenWay Gas Module
1. Using the FC200SR, program the reading of the index that was on the meter into the
OpenWay Gas Module assembly.
For initial programming, hold the FC200SR approximately 1 foot away from
the 2.4 GHz OpenWay Gas Module.
For reprogramming (30 days or more past initial programming), hold the
FC200SR approximately 4 to 5 feet away from the OpenWay Gas Module.
Be sure to program the OpenWay Gas Module to the correct mode for the reading
technology what will be used (for example, Fixed Network Mode, Mobile/Handheld
Mode, or Hard to Read Mobile/Handheld Mode). In Endpoint-Link Pro v5.0, you will
have access to the one mode that was defined by your system administrator.
During programming, the OpenWay Gas Module is programmed to the nearest 100
cubic feet; the last two digits (the tens and units) are programmed as zeros (0). Once
programming is complete, however, the module assembly can be read to the nearest
cubic foot.
2. Slowly turn the OpenWay Gas Module drive wriggler two turns in the direction
indicated on the index drive rate. This lets you verify the module is counting properly
after assembly.
IMPORTANT Do not turn the drive wriggler faster than one turn per second.
3. Read the OpenWay Gas Module assembly using the FC200SR. Consult the EndPoint-
Link ERT Programming Guide (TDC-0411) or other applicable instructions for details
on how to read an OpenWay Gas Module.
If this reading is higher than the one you programmed in step 1 above, the ERT
module assembly is counting correctly.
If the OpenWay Gas Module assembly reading is not higher than what was
programmed in step 1, replace the module with a new one.
Attach the OpenWay Gas Module to the Meter
After the OpenWay Gas Module has been programmed and is reading correctly, follow the
steps below to attach the module to the meter.