Caution: Do not program configuration changes to the Cellular 500W Pit Module
until it is connected to the water meter register.
■
The FC300SR or Itron Mobile Radio are the only devices that support programming for the
Cellular 500W Pit Module.
■
Keep a minimum of 12 inches between the Cellular 500W Pit Module and programming
device while programming configuration changes are completed.
■
Do not place the programming device antenna directly on the pit module.
Encoder-type Meter Register Connections
Pit module connections are made by the meter manufacturer for encoder-type registers. This
information describes those connections.
Caution: Itron recommends pit module connections be completed using the inline
connector. In rare instances, if a spliced connection is made, the Itron splice kit must
be used (Itron part number OEM-0034-002). For more information, see Completing
Gel-cap Connections Using the Itron Splice Kit on page 34.
Pit module wire color
Black (power/clock) White (ground)
Register manufacturer Register screw terminal
Badger
ADE
E Series
HR E LCD
HR E Mechanical
Red Black
Badger M5000 Mag Meter Red Terminal: Input + Black Terminal: Input - and Out 4-
Diehl Hydrus Red Black
Elster AMCO
InVision
Scancoder
AquaMaster
AquaMaster III
Green Black
Elster AMCO
SM 700 (Severn Trent)
Q200 (Sensus Protocol)
Red Black
Cellular 500W Module Pit Installation Guide 2 Initialization, Connection, and Programming
October 13, 2021 815-0617-00 REV000 Itron, Inc. Page 14 of 40