Installation Guide
Table Of Contents
- Cellular 500W Module Pit Installation Guide
- Contents
- New in This Document
- 1 Introduction
- 2 Initialization, Connection, and Programming
- 3 Cellular 500W Pit Module Installation
- 4 Accessory Installation
- 5 Completing Gel-cap Connections Using the Itron Splice Kit
- A Troubleshooting
- B Important Safety and Compliance Information
To mount the module in a through-lid
1. Insert the retainer clip into the pit lid hole with the convex surface on the top of the pit lid.
2. From the bottom side of the lid, screw on the threaded retainer clip collar until the beveled
top rests against the pit lid.
Note: Ensure that the beveled edge of the clip collar is toward the top of the pit lid.
3. Align and insert the retainer clip tab (1) into the retainer clip receptacle (2) on the pit
module housing.
4. Verify that the clip locks into place and the retainer clip collar is hand-tightened against the
pit lid.
Cellular 500W Module Pit Installation Guide 3 Cellular 500W Pit Module Installation
October 13, 2021 815-0617-00 REV000 Itron, Inc. Page 21 of 40
DRAFT