Installation Guide

4
Accessory Installation
This chapter provides the installation procedures for Cellular 500W Pit Module accessories,
including:
Inline Connector Installation on page 29
Remote Disconnect Valve Installation on page 30
Itron Cable Armor Installation on page 31
Leak Sensor Installation on page 33
Inline Connector Installation
Note: If an inline connector is not used or the pit module is already connected to the water
meter or register, skip this section.
1. Remove the protective environmental cap from the module connector.
Caution: Verify that the connector ends are clean and dry before assembly.
2. If any of the following conditions occur, do not install the modules.
Any of the three pins are damaged or missing.
The O-ring is missing.
The cable is cut or nicked.
3. Remove the protective cap from the register or accessory connector.
4.
Align the connectors.
Push until snug.
Twist the register cable's black coupling nut to align the two tabs.
5. Connect the register cable to the pit module connector.
October 13, 2021 815-0617-00 REV000 Itron, Inc. Page 29 of 40
DRAFT