Leak Sensor Installation
Installation of the Leak Sensor with a Cellular 500W Pit Module requires the Leak Sensor with
an inline connector (Itron part number LDS-1601-001). The Leak Sensor connects to the
telemetry connector on the pit module.
If the Leak Sensor five foot cable is not long enough to reach the Cellular 500W Pit Module, an
extension cable is available from Itron (CFG-0151-404). The maximum cable length between
the Leak Sensor and the Cellular 500W Pit Module should not surpass thirty feet.
Caution: If the pit module is installed to enable communications for the Leak
Sensor but a register is not connected, replace the register connector's cap with the
environmental cap removed from the blue telemetry connector to protect the
register connector.
Cellular 500W Module Pit Installation Guide 4 Accessory Installation