Installation Guide

3. Crimp the connector by squeezing the handles until the connector cap is fully seated.
Continue to apply pressure for three seconds.
A connector is crimped properly when the top of the movable yellow center (1) is flush with
the top of the connector body (2).
Warning! Crimping the connector forces some sealant out of connector. The
sealant protects the inside of the connector against insects, moisture, and other
contaminants. The sealant may cause minor eye and skin irritation. Avoid eye
contact. Avoid prolonged or repeated skin contact. Contact Itron Support for
Safety Data Sheets.
4. After the connections between the Cellular 500W Pit Module and the register or meter wire
are completed, arrange the connectors in a single file.