Installation Guide

Table Of Contents
Local Auditing
Note: Local auditing functionality is dependent on the module’s firmware version. For
more information, see Firmware Functionality on page 11.
The Cellular 500G supports local data auditing of installation programming. Local auditing
features the listed characteristics.
Supports writing data (in both manufacturing and by FDM) to the module to support future
installation programming auditing.
Reading the auditing data is supported locally.
Auditing parameters include FDM User ID, number of dials, meter drive rate, unit of
measure, count rate, rollover, and PComp.
Timestamping of auditing parameters.
Log access via Companion Specification for Energy Metering (COSEM) only.
Low Battery Event/Alarm
Note: For Cellular 500Gs, low-battery functionality is dependent on the module’s firmware
version. For more information, see Firmware Functionality on page 11.
The Cellular 500Gs’ low-battery events are flagged when the device reaches a 10% of battery
life remaining state. The event triggers an alarm configurable for asynchronous delivery to the
head end system.
Functional Specifications
Functional
specification
Description
Power source Single “D” cell lithium batteries
Tamper
detection
Tilt and cut cable
Regulatory and
standards
FCC compliance: Part 15.247, 15.249 (programming), 15.109
FCC IDs:
EWQ500C: for Remote Mount
EWQ500GAC: for American/Rockwell Gas meters
The Cellular modem is a Sierra Wireless HL7800 module
FCC ID: NLNHL78
ISED compliance: RSS-247, RSS-210 (programming), ICES 003
IC: 864D-50)C: for Remote Mount
IC: 864D-500GAC: American/Rockwell
Cellular 500G Module Remote Mount Installation Guide 1 Introduction
October 11, 2021 815-0622-00 REV 000 Itron, Inc. Page 10 of 99
DRAFT