5. Remove the magnet hub from the encoder and set it at least one inch away from the
encoder.
6. Use a module programming device to read the Cellular 500G. If this reading is higher than
the reading taken after the index was removed, the remote is counting and working
properly.
Note: It the reading is not higher than the previous reading, the Cellular 500G is not
working properly. Repeat steps 5 and 6. If the module count is not incrementing,
replace the Cellular 500G and perform steps 5 and 6.
7. Align the large notch in the magnet hub spacer with the needle of the index meter drive
rate dial (1 or 2 foot for residential diaphragm meters; 5, 10, or 100 foot for commercial
diaphragm meters).
8. Press the magnet hub spacer down over the dial needle as far as possible. The tip on the
bottom of the spacer may touch the index face. Turn the dial in the direction noted on the
index after the hub is in place to verify the index dial functions with a smooth, easy rotation.
9. Align the pointer (1) on the top of the magnet hub and the notch (2) in the side of the
magnet hub with the needle (3) of the meter drive rate dial.
Cellular 500G Module Remote Mount Installation Guide 4 Specific Meter Manufacturer Installation
October 11, 2021 815-0622-00 REV 000 Itron, Inc. Page 27 of 99