5. Align the inside mounting rail screw holes over the back index and corrector mounting
screw holes.
6. Insert the two remaining mounting screws in the corrector bracket mounting holes.
7. Tighten all four mounting screws.
Mechanical and Wiring Installation Instructions
This section provides wiring and connection information for compatible Eagle Research
products. Refer to the instruction for your product type.
Connecting to the MPplus Corrector
1. With the MPplus door open, insert the flying leads from the Cellular 500G into the
compression connector on the left of the MPplus housing.
2. Pull the lead wires through the compression connector until there is adequate wire to
reach the terminal blocks labeled 15, 16, 17, 18, 19, 20, 21, and 22.
3. Tighten the compression connector.
4. Twist the Cellular 500Gās blue and white wires together.
For uncorrected reads
5. Connect:
ā
the twisted blue and white wires to terminal 17 on the MPplus terminal block.
ā
the red Cellular 500G wire to terminal 18 on the MPplus terminal block.
6. Close and latch the MPplus corrector door.
Cellular 500G Module Remote Mount Installation Guide 4 īSpecific Meter Manufacturer Installation