Installation Guide

Table Of Contents
Using Eagle Research Field Manager to Change the MPplus Settings
1. Open the Eagle Research Field Manager from the Start menu or the desktop shortcut.
2. Connect the communications cable from your computer into the MS connector on the side
of the MPplus corrector. After the MS connector is connected, take note of the baud rate
displayed on the front of the corrector.
3. Click Connect on the upper left corner of the Field Manager window. A Connect to
Remote window opens.
4. Select the following parameters:
Connection Type: Direct
Communications Port: enter your computer’s port number
Baud Rate: enter the baud rate that displayed in Step 3.
5. Click OK.
6. Click View/Config.The Field Manager window opens and displays the settings for the
current connection.
Cellular 500G Module Remote Mount Installation Guide 4 Specific Meter Manufacturer Installation
October 11, 2021 815-0622-00 REV 000 Itron, Inc. Page 40 of 99