Important! Use a crimping tool compatible with gel-connectors. Do not use
standard pliers for crimping gel-connects. For more information, see Using Gel-
cap Connectors to Complete Wiring Connections on page 92.
American meter wire Cellular 500G wire
Black Blue
White White
Red Red
5. Insert the meter cable through the slot on the Cellular 500G backplate. Install a cable tie to
the meter cable wire below the meter cable insulation to provide strain relief.
6. Tuck the connectors and cable tie into the Cellular 500G housing. Place backplate on the
assembly and tighten the four backplate screws using a size T-10 Torx screwdriver.
Cellular 500G Module Remote Mount Installation Guide 4 Specific Meter Manufacturer Installation
October 11, 2021 815-0622-00 REV 000 Itron, Inc. Page 48 of 99