4. If you change a variable, click Update Values to complete the change.
5. Select the Configuration tab to view the volume configuration or confirm the volume
configuration and pulse settings. Use the drop-down lists to change the variable’s setting.
Note: You must click OK to complete any setting changes.
Testing IMC or W2 Communication with GE User Terminal (UT) Communication
Software
1. Connect the IMC/W2 to the PC using the serial cable.
2. Using the GE Dresser User Terminal (UT) communications software, connect to the
IMC/W2.
3. Read the uncorrected or corrected count number on the Cellular 500G with the Itron
endpoint reading device. Compare the IMC/W2 uncorrected or corrected amounts to
those fro. The Cellular 500G.
4. Input approximately 20 pulses to the Cellular 500G. Verify that the uncorrected or
corrected counts on the IMC/W2and the Cellular 500G are the same.
Programming Notes
The following table lists pulse rates for the pulse output of compatible GE indexes.
Index style Meter size
8C-11M 16M 16M-56M 1.5-11M 16M-102M
B3 CTR index 10 100
B3 TC index
(Meter built 1/1999 and beyond)
10 100
B3 TC index
(Meter built prior to 1/1999
50 500
LMMA CTR index 10 100
LMMA TC or Series 3 CTR/TC
index
100 10
Honeywell Instrument Installation
Note: This meter is compatible only with devices running on the network.
This section provides installation instructions for the Cellular 500G on the following compatible
Honeywell Instruments.
Cellular 500G Module Remote Mount Installation Guide 4 Specific Meter Manufacturer Installation