Meter model Meter notes Module type Itron part
number
Module notes
Mini-AT
Mini-Max
EC-AT
Pressure and temperature electronic
volume instruments. Instruments must
have a Form A board.
Form C is NOT supported. .
Item #56 Pulse Scaling Factor must be
2.0.
Item #96 Cor Vol Display must be 7, 6, 5,
or 4 digits (1, 2, 3, or 4 blanks).
Item #115 Output Pulse Code must be set
at 1, 2, or 4.
For connection to Mini-Max only, Item
#115 must be set at 1 or 2.
Item 124 wake up setting on Honeywell
corrector must be set to 1.
Compatible corrector firmware versions
are 2.5020 and 2.73.
500G remote ERG-7000-502
Meter model Meter notes Module type Itron part
number
module notes
TCI
Temperature Compensating Index. TCI must
have a Form A board, Form C is NOT
supported. Item #56 Pulse Scaling Factor must
be 2.0. Compatible TCI firmware versions are
1.06, 1,07, and 1.10.
500G remote ERG-7000-502
ERG-7000-503
The -502 module has a
5 inch cable and is
used when longer
cabling is required.
This module will return
the cut cable tamper.
The -503 module has
lead wires designed for
use with the TCI
mounting bracket. This
module will return the
cut cable tamper.
Overview
Installing the Cellular 500G to a Honeywell Instrument involves the following tasks.
Cellular 500G Module Remote Mount Installation Guide 4 Specific Meter Manufacturer Installation
October 11, 2021 815-0622-00 REV 000 Itron, Inc. Page 65 of 99