8. Tighten the large strain relief securely.
Warning! Do not crush the module through-cables when tightening the strain
relief.
9. Re-install or reconnect the power or battery sources.
10. Close the instrument case and tighten the case screw securely. Replace any locks that
were removed for installation.
11. Install the Cellular 500G. See Mounting on page 12.
Connecting to the Honeywell TCI
The Honeywell Instruments Temperature Compensating Index (TCI) provides two Form-A
volume pulse outputs and one Form-B alarm outputo these outputs are electronic switches.
The Form-A pulse outputs are configurable for compensated or uncompensated volume. The
Form-B output is for alarm output use only.
Connections to the three output pulse channels are completed using loose unterminated wires
(the individual wires from a cable) and gel-connectors. The TCI unit has six unterminated
wires that require six gel-connectors (Itron part number CON-0023-001) to enable pulse
connections to ancillary devices. Loose wires are located inside the gray adapter plate behind
the black strain relief fitting.
Strain relief fitting Honeywell TCI strain relief
tether
Backplate black fitting with
loose cable wires (Honeywell