Romet Meter Installation
This section describes installation for Romet meters and correctors compatible with Itron
Cellular 500Gs.
Meter model Meter notes Module type Itron part
number
module notes
RM Series STD CTR 600-
5600
TC 2000-23000
Meter must have
factory-installed
pulser with
connector output.
Purchase cable
interface from
manufacturer.
Cellular 500G ERG-7000-
503
RM Series Electronically
compensated meter ECM2
60-56000
Meter must have
connector pin with
factory-installed
pulse output.
Purchase correct
cable interface
from Romet.
AdEM
®
Series Correctors
including AdEM-S
®
, AdEM-
T
®
, and AdEM
®
-PTZ
Must be
configured to 350
ms of output pulse
spacing and 30
ms of output pulse
width.
Overview
Cellular 500G installation with the Romet series correctors involves the following tasks:
1. Programming or verifying the that corrector is set up to work with the Cellular 500G.
Programming requires a computer loaded with the RometLink software and a Romet
computer-to-corrector communication cable.
Cellular 500G Module Remote Mount Installation Guide 4 Specific Meter Manufacturer Installation
October 11, 2021 815-0622-00 REV 000 Itron, Inc. Page 78 of 99