2. Insert the mounting screw fitted with the three lock washers. Two lock washers are used
as spacers (as shown).
.
3. Attach the mounting plate to the meter. Insert the mounting screw where the module screw
was removed. Torque the mounting screw to 5-7 foot pounds to secure the plate to the
Romet meter.
4. Moun. The Cellular 500G using the pre-drilled holes on the mounting plate and the module
mounting screws.
5. Place new tamper seals over the two screws. Press tamper seals into place using an
11/32 inch nut driver or similar blunt tool.
6. Connect the module to the meter using the previously installed cable interface.
Cellular 500G Module Remote Mount Installation Guide 4 Specific Meter Manufacturer Installation
October 11, 2021 815-0622-00 REV 000 Itron, Inc. Page 80 of 99