Installation Guide

Table Of Contents
4. Set the ECM2 output pulse spacing to 750 ms for operation with the Cellular 500G. Output
spacing represents an off-time between pulses.
Sensus Meter Installation
This section describes Cellular 500G installation on compatible Sensus meters.
Meter model Meter notes Itron part number
Sonix pulse output 12, 16, 25, 57
(Metric)
600, 880, 2000 (cubic foot)
Sonix meters are pulse output
registers which are programmed by
Sensus software. Proper pulse output
options and display options must be
selected.
ERG-7000-503
Overview
Installing the Cellular 500G to a Sensus meter involves the following tasks:
1. Programming the meter.
2. Mounting the Cellular 500G. The module may be mounted on a pipe or flat surface (see
Mounting on page 12). Select the mounting option appropriate for your installation.
Mounting options include:
Wall mount on a sheet metal surface
Pipe mount using the Itron pipe mount kit CFG-0005-003
3. Connecting the Cellular 500G to the meter.
4. Programming the Cellular 500G. For programming information, see Programming on page
18.
Mounting Instructions
The Sensus factory can direct mount the Cellular 500G to Sensus Sonix Meters (contact
Sensus North American Gas Customer Service for mounting specifications and ordering
information). This section includes the instructions for customers to mount the module on the
Sonix meter using the mounting materials available from Sensus Metering Systems.
Cellular 500G Module Remote Mount Installation Guide 4 Specific Meter Manufacturer Installation
October 11, 2021 815-0622-00 REV 000 Itron, Inc. Page 89 of 99