Mechanical and Wiring Installation Instructions
Sensus Sonix meters provide a standard Form A electronic pulse output compatible with the
Cellular 500G. You may connect the Sensus Sonix meter to the Cellular 500G using the pulse
output cable or you can directly mount the Cellular 500G to the meter.
Sensus meter wiring
Sensus Sonix 2000 meter pulse output options
Option (1) Pulse 1 (+) (2) Pulse 2 (+)
(3) Ground (-)
1 Uncorrected Corrected
2 LCD index volume Alarm
Sensus Sonix 600 or 880 meter wiring
Meter wire Module wire
Red White and blue
Black Red
For more information about programming wiring parameters, contact Sensus North American
Gas Customer Service.
Programming and Requirements Notes
Using the SonixCom software, configure the Sensus Sonix meter parameters with the
following the Sensus pulse output settings.
1 pulse per 10 cf
1 pulse per 100 cf
1 pulse per 1000 cf