Using Gel-cap Connectors to Complete Wiring
Connections
This section provides the instructions to complete Cellular 500G to meter wiring connections.
Gel-cap connections require:
■
E-9R 3M
®
gel-cap crimping tool
■
3M gel-cap connectors (Itron part number CON-0023-001)
1.
Push the two wires into the connector as far as possible.
Caution: Do not strip insulation from the ends of the wires before inserting them
into the connector.
2. Place the connector and connector wires into the jaws of the crimping tool. Ensure that the
wires remain fully inserted in the connector.
3.
Squeeze the handles to crimp the connector. Apply pressure until the cap is fully seated
(at least three seconds)