 Unit Installation 
OpenWay® Riva™ CAM / ACT Coupler Unit  26
Install CGR Mounting Bracket 
Illustration Callout Number  Description 
1 
Alignment slots 
2 
4 - Hex head mounting bolts (8mm x 25mm) 
supplied with the installation kit 
3 
Center stud with self-locking hex nut 
1.  Position the CGR mounting bracket over the center stud and slid down behind hex nut. 
2.  Insert the four 8mm x 25mm mounting screws supplied with the installation kit into the threaded holes in 
the base mounting plate. Do not tighten bolts until all are started. 
Note The four alignment slots in the mounting brackets allow the CGR and the coupler unit to be rotated 
either clockwise or counter clockwise for alignment purposes. Inserting the mounting bolts as shown 
allow the unit to rotate counter clockwise. Inserting all four bolts in the holes at the other end of the slot 
allows the unit to be rotated clockwise. 
3.  Adjust the alignment of the CGR and coupler to the desired orientation and tighten the four mounting 
bolts and the hex nut on the center stud. Use a torque of 6-7 foot-pounds when tightening the bolts and 
nut. 