When the OpenWay Riva Gas Remote Disconnect is mounted in horizontal piping, mount
the device with the top surface (the area with the product label) away from walls and
structures.
When the OpenWay Riva Gas Remote Disconnect is mounted on vertical piping, do not
mount the device in a vertical downflow position (with the flow arrow point down). The top
surface (the area with the product label) may point to the side but not toward nearby walls or
structures.
Following these installation best practices will optimize communications and prevent debris
from accumulating on the valve seal surface.
OpenW
ay Riva Gas Remote Disconnect models
The OpenWay Riva Gas Remote Disconnect is available in the listed models.
OpenWay Riva Gas Remote Disconnect description Itron part number
OpenWay Riva Gas Remote Disconnect, 1-inch GRD-7103-001
OpenWay Riva Gas Remote Disconnect, ¾-inch GRD-7103-002
Flood sensor, resistive type, with 4' armored cable TEL-7103-004
Flood sensor, resistive type, with 8' armored cable TEL-7103-008
OpenWay Riva Gas Remote Disconnect system
security
The OpenWay Riva Gas Remote Disconnect is a component of Itron's OpenW
ay Riva
system. The OpenWay Riva system enhanced security, provided by Itron Security Manager
(ISM), applies to the RF communications between the network or handheld and the
OpenWay Riva Gas Remote Disconnect. There are two fundamental security processes
used in the Itron Security Manager to ensure system communication confidentiality and
validity.
About the OpenWay Riva Gas Remote Disconnect
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 8