Continue the OpenWay Riva Gas Remote Disconnect deployment by commissioning the
valve. Commissioning requires an Itron programming or reading device loaded with FDM
Tools.
Commission instructions
1. Using FDM Endpoint Tools, select 4. Commission.
2. Enter the OpenWay Riva Gas Remote Disconnect Device ID.
3. Select Next.
4. Select 1. Valve Status to confirm the valve is commissioned.
5. Decommission
In the event the OpenWay Riva Gas Remote Disconnect will be removed from service, the
device must first be decommissioned.
Warning: Prior to decommissioning the OpenWay Riva Gas Remote Disconnect,
verify the gas supply is turned off. Decommissioning the OpenWay Riva Gas
Remote Disconnect:
returns the device to Factory Ship Mode with security enabled
disables the valve operations
disables some events (for example, tilt tamper)
To recommission the OpenWay Riva Gas Remote Disconnect, the user must get the
proper signed commands from FDM and ISM to recommission the device.
Performing a Check Endpoint with FDM Tools will not recommission the OpenWay
Riva Gas Disconnect.
Decommissioning instructions
1.
Select number 5, Decommission in FDM Endpoint Tools Enhanced.
2. Click Next.
3. Enter the OpenWay Riva Gas Remote Disconnect device ID.
4. Click Next.
A window displays confirming the OpenWay Riva Gas Remote Disconnect was
successfully decommissioned.
OpenWay Riva Gas Remote Disconnect Operations
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 26