Datasheet

27
www.ittcannon.com
Dimensions shown in mm (inch)
Specifications and dimensions subject to change
Cannon Trident Connectors
Ringlock Circular Connectors
Test Method Criteria of Acceptance
Dielectric Withstanding Voltage 1550 V ac for 60 seconds No breakdown
2500 V ac for 60 seconds (Size 1807 only) No breakdown
Thermal Shock -55°C to +125°C (-67°F to +257°F), 5 cycles No physical damage.
Physical Shock 50 g’s peak, 3 axes, No physical damage.
11 millisecond duration half-sine pulse No loss of continuity >1 sec
Vibration 10 g’s peak,10-500 Hz, 9 hours No physical damage.
No loss of continuity >1 sec
Durability 500 cycles of mating and unmating, No mechanical or
500 mating cycles max Electrical defects
Salt Spray 48 hours Shall be capable of mating and unmating
and meet contact resistance requirements
High Temperature Endurance 1000 hours at 125°C (+257°F) Insulation Resistance > 100 MΩ
Humidy Steady State RH 90-95%, 40°C(+104°F), 504 hours Insulation Resistance > 100 MΩ
Moisture Resistance 10 Cycles Insulation Resistance > 100 MΩ
The table below summarizes the results of key tests. Data is applicable to standard connectors with standard contacts.
Variations may affect this data, so please consult factory for further information on your requirements.
Test Specifications
How to Order-Connectors
Typical Nomenclature: TR 16 19 PM
S1NB
Series
TR = Trident Ringlock
Shell Number of
Size Contacts
10 04
12 08
14 12
16 19
18 07
18 23
20 28
22 35
24 48
Color
B = Black
Material
N = Nylon
Series Identification
1 = Standard
S = Standard
H=Interface Sealing*
P=Plastic Coupling Nut**
M = Accepts Male Contacts
F=Accepts Female Contacts
P=Plug
R=Receptacle
* Receptacle only
** Shell size 16 and 24 only