Protect sensitive electronics in voice and data communication systems
from damage caused by transient voltages with 100% solid-state over-
voltage protection. Current surge protection is provided through sneak
current fuses or self-resetting PTC’s.
Features:
66 Block Connectivity—Fits all 66 Type M Blocks
Dual Indicator Lights—Protection OK and Ground Connection OK
Solid-state Protection—Provides the fastest response to transient voltages
(2–5 nanoseconds) by quickly diverting damaging surges to ground and resetting.
Single Pair Protection—Scale the protection to the system size. Protect only the lines
requiring protection.
Lifetime Product Warranty—For up-to-date warranty information visit:
itwlinx.com
Cost Savings—Eliminate expensive five-pin blocks while using economical 66 Blocks.
Streamlined Installation—Eliminate redundant cross-connects by adding protection
directly at the 66 Block. Press fit protectors to the the block attaching the ground bar
MGB-1 to the protectors. A Screw Ground Lug (SGL-1) is required.
Optimum Protection—Available in a number of voltage ratings to match system
operating voltages.
Ideal for Retrofit Applications—just remove the bridging clips from the block and replace them with the UltraLinx Protector, add the ground connection and the pair is
protected!
Sneak Current Protection—Protects against fires caused by overloads and power crosses.
SPECIFICATIONS
UP3B version is UL Listed as both Primary and Secondary Protector with 350 mA fuse.
UP3H, UP3P are UL Listed as Secondary Protectors and contain self-resetting PTC’s to eliminate service calls.
UP3H version is designed specifically to protect high speed T1, xDSL data lines without harming the transmission integrity.
Ordering Information:
itwlinx.com 1-800-336-LINX
Designs and specifications subject to change
without notice due to product improvement
S
ta
n
d
a
rd
6
6 b
lo
c
k
UP3B
UP3H
UP3P
Part Numbers
2.62
×
1.88
×
0.38
2.62
×
1.88
×
0.38
2.62
×
1.88
×
0.38
Dimensions
L" × W" × D"
Voice / Fax
T1 / xDSL / ISDN
Voice / Fax
Application
Solid State
350 mA
160 mA
160 mA
Fuse Rating
Primary
Secondary
Product Selection
0–26.9 Volts
27.0–35.0 Volts
35.1–60.0 Volts
200 Volts Peak
Maximum
Operating Voltage
(Includes AC & DC voltage)
27
39
75
235
Clamping
Voltage
Voice / Fax /
Modem Lines
350 mA Fuses
Voice / Fax /
Modem Lines
160 mA PTC
UP3B-27
UP3B-39
UP3B-75
UP3B-235
UP3P-27
UP3P-39
UP3P-75
UP3P-235
T1 / E1 xDSL /
ISDN / LAN
160 mA PTC
UP3H-27
UP3H-39
UP3H-75
UP3H-235
UltraLinx Part Numbers for use on 66 Blocks
Easy
Plug-On
Connection
Ergonomic Grip
for Easy Removal
Tool Grip for Easy Removal
Ground Status Indicator
Protection Status Indicator
Ergonomic Grip
for Easy Removal
Ground Connection
(Compatible with
existing grounds)
Push-Button for
Ground Indication

Summary of content (1 pages)