Installation Guide

10
Leading the Way
IVC US Residential Installation Guide – Sheet Vinyl Flooring
double layer construction. Porous wood underlayments must be primed.
- Any failure of the underlayment or ooring due to the underlayment is NOT the
responsibility of IVC US. IVC US does not recommend installing resilient ooring
over wood ooring or suboors applied directly over concrete or sleeper-
construction oors.
• Concrete — See Grade Levels below:
Grade Levels
Suspended: An acceptable suspended oor is a concrete or wood substrate with a
minimum of 18” (460mm) of well-ventilated air space beneath it. IVC US recom-
mends that a moisture vapor barrier be placed on the ground below the air space.
On-Grade: An acceptable on-grade oor is a concrete substrate in direct surface
contact with the ground at the surrounding ground level. The concrete
slab should be protected from moisture penetration and incorporate a
proven moisture vapor barrier.
Below-Grade: An acceptable below-grade oor is a concrete substrate partially or
completely in contact with the ground below the average surrounding ground level.
The concrete slab should be protected from moisture penetration and incorporate a
proven moisture vapor barrier.
• VCT (well bonded, on and above grade)
• Ceramic (well bonded)
• Terrazzo (well bonded)
• Self-leveling and patching compounds (latex fortied Portland cement based only)
• Resilient oor (no more than 2 layers, well bonded, non-cushioned – residential
applications only)
• Radiant heat oors (not exceeding 85°F (29°C) and approved by the manufacturer for the
use of their product with resilient vinyl ooring applications)
• OSB (underlayment grade)
OSB underlayment panels must be underlayment grade as specied and warranted by
the manufacturer. Underlayment panels and joints must be fastened and reinforced
according to manufacturer’s instructions. Completely sand the oor with a oor sander,
so that the oor is smooth and at. Note: The chips in OSB overlap. Without sanding
properly, OSB has high and low spots throughout the oor that could telegraph through
the vinyl.
- Surface must be primed using IVC FLEX-PRIM Acrylic Latex Primer.
• Particle board (underlayment grade)
Particle board underlayment panels must be underlayment grade as specied and war-
ranted by the manufacturer.
- Surface must be primed using IVC FLEX-PRIM Acrylic Latex Primer.
Unacceptable Surfaces:
• Inter-ex and any perimeter bonded products • Carpet
• Any oating oor system • Cork
• Resilient tile installed below grade • Cushion-back vinyl
This document is reviewed on an ongoing basis. Control # MKF_0012_0 8/13/13