User manual
Exchanging the storage battery
This device is equipped with a 3V Lithium Button-Cell Battery of type CR2032 to support the time and the set mode in case of power
failure.
Avoid losing your saved data in case of power failure by replacing this battery approx. every 5 years.
Opening the housing
Attention – Before opening the housing, it is strictly necessary to disconnect the mains plug.
Attention – Explosion hazard in case of improper exchange! Replace this battery by an equivalent type only.
Release the four screws on the top of the device and remove the upper part. In the upper part the button-cell battery is now visible
on the printed circuit board. Remove the old battery and insert the new one into the battery holder observing correct poling. The
positive pole of the battery points outwards. Close the housing after replacing the battery. Now you may reconnect the device to the
230V socket and take it into operation. In case of doubt contact a specialist.
Possible malfunctions
MALFUNCTION
SOLUTION
• No display • Plug the connector plug of the device into the mains plug
• Check power supply
• Device switches off the pump
as long as there is no hot water
everywhere
• Set shorter measuring interval time
• Set longer pump operating time
• Set smaller differences in temperature
• Pump is switched on too often,
although no water has been
taken
• Extend distance between flow probe and buffer storage
• Avoid draught on the probes
• Check contact of temperature probes to pipe.
• Pump is not switched on after
taking water
• Pump does not start if circulation contains sufficient hot water
• Check contact of temperature probes to pipe
• Increase temperature in the hot water tank
• Set shorter measuring interval time
• Set longer pump operating time
• Display indicates “Err“
- Temperatures outside the
measuring range (0-100°C)
- Temperature probe or supply
pipe is damaged
• Check temperature probes, if applicable, observe the operating temperature
of the device.
• Repair by manufacturer
Technical specifications
Operating voltage: 230 V AC
Power consumption: 1 W; with pump operation and backlight 2.5 W
Protection class: I
Max. switching capacity: 450 W
Measuring range of the temperature probes: 0°C to 100°C
Display: 16 characters x 2-line alphanumeric LCD
Storage battery: 3 V, CR 2032
Temperature range: 0 to 50°C
Weight: 750 g
Dimensions: 160 x 80 x 75 mm
Cable length of connection cable: 150 cm
Cable length of temperature probes: 290 cm each probe
We give two years warranty on the economy control for circulation pumps. Please take note that we are not responsible for
operation and/or connection errors. We cannot assume any liability for damages resulting from this.
Environmental Protection Notice
At the end of its useful life, this product must not be disposed of together with normal household waste, but has to be dropped off at a
collection centre for the recycling of electrical and electronic devices. This is indicated by the symbol on the product, on the instruction
manual or on the packaging. The materials of which this product is made are recyclable pursuant to their labeling. With the reuse, the
recycling of the materials or other forms of scrap usage you are making an important contribution to the protection of the environment.
Please ask your local administration office for the appropriate disposal center.
Technical specifications subject to change. We assume no liability for typographical errors. 05/2009
IVT Innovative Versorgungs-Technik GmbH, Dienhof 14, D-92242 Hirschau
Phone: 09622-719910, Fax: 09622-7199120 www.IVT-Hirschau.de; Info@IVT-Hirschau.de