Installation Instructions

1) Find the appropriate threaded holes on mounng
strap[A]. Assemble mounng screws[B] into threaded
holes.
2) Aach mounng strap to outlet box[D] using the
strap mounng screws[C]. The mounng strap can be
adjusted to suit posion of xture.
3) Thread the canopy[E] with stem into the coupler on top
of the main body[H].
4) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
5) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
6) Push xture to ceiling, carefully passing mounng screws
through holes in canopy. NOTE: Be certain wires do not
get pinched between canopy and ceiling.
7) Use knobs[F] and lockwashers[G] to secure canopy.
Tighten to secure.
8) Put into place the twelve (12) crystal rods[I] and using
the supplied alan wrench[J], secure the crystal rods into
place with the set screws[K]. Do not over ghten.
9) Thread into place the sixteen (16) short rods[M] and
the sixteen (16) long rods[L] into the main body as
shown. Note that the rods can be installed to customer
preference for locaon.
10) Install the recommended bulbs. (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
[A] Mounting
Strap
[B] Mounting
Screws
[C] Strap
Mounting
Screws
[D] Outlet Box
[E] Canopy
[F] Knobs
[G] Lockwashers
[H] Fixture Body
[I] Crystal Rods
[J] Alan Wrench
[K] Set Screws
[L] Long Rods
[M] Short Rods
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
A
E
B
G
F
C
L
J
K
M
I
D
H

Summary of content (2 pages)