SDS
Safety Data Sheet
According to HCS-2012 APPENDIX D TO §1910.1200
Version: 1.0/EN
Revision date: 23-Nov-2018
Product name: Li-Polymer Rechargeable Battery
Printing date: 23-Nov-2018
-- Page 5 / 11 --
replace all batteries by new ones of identical type and brand. Do not swallow batteries. Do not throw batteries into
water. Do not throw batteries into fire. Avoid deep discharge. Do not short-circuit batteries Use recommended charging
time and current.
(b) Conditions for safe storage, including any incompatibilities
If the Lithium-ion Battery is subject to storage for such a long term as more than 3 months, it is recommended to
recharge the Lithium-ion Battery periodically. Operating temperature: Charge:0℃~45℃. Discharge: -20℃~60℃ And
recommended at -20℃~45℃ for 1 month storage, at -20℃~35℃ for 3 months storage. The capacity recovery rate in
the delivery state (50% capacity of fully charged) after storage is assumed to be 80% or more. The voltage for a long
time storage shall be 3.7V~4.2V range. Do not storage Lithium-ion Battery haphazardly in a box or drawer where they
may short-circuit each other or be short-circuited by other metal objects. Keep containers tightly closed in a dry, cool
and well-ventilated place. Protect from moisture. Store locked up. Keep out of reach of children.
8. Exposure controls/personal protection
(a) Control parameters
Exposure Guidelines
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Lithium Cobalt Oxide (CoLiO2)
12190-79-3
TWA: 0.02 mg/m³
Graphite
7782-42-5
TWA: 2 mg/m3 respirable
fraction all forms except
graphite fibers
TWA: 15 mg/m3 total dust
synthetic
TWA: 5 mg/m3 respirable
fraction synthetic
(vacated) TWA: 2.5 mg/m3
respirable dust natural
(vacated) TWA: 10 mg/m3
total dust synthetic
(vacated) TWA: 5 mg/m3
respirable fraction synthetic
TWA: 15 mppcf natural
IDLH: 1250 mg/m3
TWA: 2.5 mg/m3 respirable
dust
Phosphate(1-), hexafluoro-, lithium
21324-40-3
TWA: 2.5 mg/m3 F
TWA: 2.5 mg/m3 F
TWA: 2.5 mg/m3 dust
(vacated) TWA: 2.5 mg/m3
Nickel
7440-02-0
TWA: 1.5 mg/m3
TWA: 1 mg/m3
(vacated) TWA: 1 mg/m3
IDLH: 10 mg/m3
TWA: 0.015 mg/m3
Copper
7440-50-8
TWA: 0.2 mg/m3 fume
TWA: 1 mg/m3 Cu dust and
mist
TWA: 0.1 mg/m3 fume
TWA: 1 mg/m3 dust and mist
(vacated) TWA: 0.1 mg/m3 Cu
dust, fume, mist
IDLH: 100 mg/m3 dust, fume
and mist
TWA: 1 mg/m3 dust and mist
TWA: 0.1 mg/m3 fume
Aluminum foil
7429-90-5
TWA: 1 mg/m3 respirable
fraction
TWA: 15 mg/m3 total dust
TWA: 5 mg/m3 respirable
fraction
(vacated) TWA: 15 mg/m3
total dust
(vacated) TWA: 5 mg/m3
respirable fraction (vacated)
TWA: 5 mg/m3 Al Aluminum
TWA: 10 mg/m3 total dust
TWA: 5 mg/m3 respirable
dust
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value
OSHA PEL: Occupational Safety and Health Administration - Permissible Exposure Limits Immediately Dangerous to Life
or Health