User's Manual

EmulationEngine 11a/b/g User's Guide
Rev #/Date: 2.0.0 Beta/07.17.03 9-1
CHAPTER 9: Troubleshooting
Login Name and/or Password Recovery
If configuration records for your EmulationEngine are lost and you
do not remember its user name or password, it may not be
possible to log in to the device. If this should happen, a special
login sequence will direct the EmulationEngine to reset the login
name and password to their factory defaults.
Open a telnet connection to the device
At the login prompt, type RESET in response to the EE login
prompt and FACTORY in response to the Password prompt. These
are both case sensitive. Example:
EE login: RESET
Password: *******
In response to this sequence, the EmulationEngine will reset both
the login username and the login password to their factory
defaults (User Name: Admin, Password: EE). A new configuration
file with the reset login and password will be written to the Flash
file system, and the EmulationEngine will issue a new login
prompt. No other configuration parameters are affected by this
operation.
You may now log in using the factory default login name (Admin)
and password (EE). Following successful login, you may use the
"set login" or "set password" CLI commands to set these
parameters as desired. Be sure to record the new settings for
future reference.
Using a Third-Party Load Generator
Symptom: Telnet or the Web Client becomes unresponsive during
a test or cannot connect at the conclusion of a test.
Possible Problems:
If your Load Generator exceeds the maximum 802.3 rate specified
in the EmulationEngine Specifications during a test: 1) Telnet
and/or the Web Client may not be able to establish a new
connection. 2) If connected, Telnet and/or the Web Client may lose
connectivity to the EmulationEngine.
If Telnet or the Web Client become unresponsive during a test or
cannot connect at the conclusion of a test, make sure your Load
Generator is not responding to ARP requests that are targeted to
the EmulationEngine address. If this occurs, the ARP request
transmitted from the PC Client (running telnet) or the Web Client
for the purpose of obtaining the MAC address of an IP address,
will respond with the Load Generator's MAC address instead of the
EmulationEngine's MAC address. All data sourced from the PC