User's Manual

Communication Machinery Corporation (CMC)
9-2 Rev #/Date: 2.0.0 Beta/07.17.03
client would incorrectly be destined to the Load Generator instead
of the EmulationEngine.
Web-Based User Interface Login Error
If you are running a personal firewall product (e.g., ZoneAlarm,
McAfee's software firewall, etc.) on the command PC, the following
error dialog may be displayed by your browser immediately
following successful log-in to the EmulationEngine web server:
If this error dialog is displayed, just click the No button to
continue. This error has not impact on the operation of the web-
based user interface or the EmulationEngine.
Hardware Installation/LEDs
Power LED: When you apply power to the EmulationEngine, the
power LED (the left-most LED facing the front of the unit) should
flash momentarily and then light ON (solid). If this does not occur,
check the power cable connection and/or the power outlet where
the power supply is installed. If power is being supplied to the unit
and the Power LED remains off, it may indicate that the
EmulationEngine’s software image file (EE22.SYS) cannot be
loaded into flash (i.e., corrupted or does not exist).
Ethernet LED: When you attach the Ethernet cable between the
command PC and the EmulationEngine, the Ethernet link LED
(the middle LED) should flash momentarily and then light ON
(solid). This should occur if you are attaching directly to the
EmulationEngine using a cross-over cable or through a
hub/switch using a straight cable. If the LED remains OFF, check
the cable connections. If the LED remains OFF, one or more of the
following problems may exist:
Incorrect or defective cable
Defective hub/switch
Using the wrong port on a hub/switch (i.e., uplink port instead of
10/100 port)
EmulationEngine Busy or Not Responding
The status bar in the top-right corner of the web-based user
interface main page shows the status of the EmulationEngine with
the System Under Test.