User's Manual

EmulationEngine 11a/b/g User's Guide
Rev #/Date: 2.0.0 Beta/07.17.03 D-1
APPENDIX D: Error and Status Messages
The EmulationEngine may display the following error and status
messages in response to incorrect or unexpected user actions or
WLAN activity.
EmulationEngine or Virtual Station Control Messages
Message Description
EE Lost SUT (no
beacons)
The EmulationEngine was joined with the System
Under Test but has stopped receiving beacons from
it.
EE Not joined with
System Under Test
A requested operation could not be performed
because the EmulationEngine is not joined with a
System Under Test.
Internal system error A requested operation resulted in an unspecified
internal error.
Invalid message
identifier
Internal error: the vSTA control task received a
Command message with an invalid message
identifier.
Invalid object identifier The vSTA control task received a GET or SET
Command message with an invalid Object identifier.
Invalid object value The vSTA control task received a SET Command
message with an invalid object value.
Invalid operation Internal error: the vSTA control task received a
Command message with an invalid operation code.
Invalid vSTA identifier The vSTA control task received a Command message
with an invalid vSTA identifier.
Invalid vSTA state for
operation
A requested operation could not be performed
because the specified vSTA is not in the appropriate
state.
vSTA idle A requested operation could not be performed
because the specified vSTA is in the Idle state.
vSTA not configured A requested operation could not be performed
because the specified vSTA has not been Configured.
vSTA not idle A requested operation could not be performed
because the specified vSTA is not in the Idle state.
vSTA not initialized A requested operation could not be performed
because the specified vSTA has not been Initialized.
vStaControl() Err writing
NOTIFY into UI's queue
The vSTA control task cannot post a message
because the UI task’s queue is full. This may occur if
a web user logs out while the EmulationEngine is
running and so may be ignored.
vStaControl() Task for
NOTIFY no longer exists
The vSTA control task cannot post a message
because the UI task is no longer present. This may
occur if a telnet user logs out while the
EmulationEngine is running and so may be ignored.