Instructions

Configuration as PC Interface with VCI Driver 15 (62)
6 Configuration as PC Interface with VCI Driver
The CANblue II can be configured as a PC interface with the VCI driver for Windows.
HMS recommends to reset the device to factory settings for optimal performance.
Parallel usage with bridge mode is possible with reduced receive and transmit performance.
Existing CAN filters are cleared in VCI mode and restored when the VCI mode is closed.
Make sure that the VCI driver and the CANblue II software package are installed (see
Installing the Software, p. 10).
Make sure that the virtual Config COM port is installed (see Installing the Virtual COM Port,
p. 12).
Install the hardware according to the instructions in the Installation Guide VCI Driver.
Make sure to access the Device Server Control with administrator rights.
Configure the device with a VCI based tool, for example with the canAnalyser Mini
(included on delivery CD).
To test if the device is connected, check the list of available devices in the canAnalyser
Mini.
CANblue II User Manual 4.01.0126.20000 EN 3.2