Instructions

Configuration as Generic PC Interface or as Bridge 18 (62)
7.1.3 Examples
CANblue II command and CANblue II reply:
>c can_init 1000
I OK: CAN_INIT
Local command and local output:
>#print CANblue Generic
# CANblue Generic
7.2 Configuring an Interface
The installed virtual Config COM port is used to configure the CANblue II to exchange data with
a CAN network connected to the CANblue II.
Make sure, that the software package and the virtual COM port are installed.
Start and configure the desired configuration tool (see Configuration Tools, p. 16).
Reset the device to factory settings with command D SETTINGS_DEFAULT.
Existing filters and settings are deleted.
Factory settings are set (information about settings see Reset to Factory Settings, p.
23).
Initialize the CAN controller with the desired baud rate with command
C CAN_INIT <baudrate>.
Set the filter (see Configuring the Filter, p. 22).
Specify further settings (see Settings in Generic Mode, p. 22).
Check the configuration with command C CONFIG SHOW.
Save the configuration with command C CONFIG SAVE.
Start the CAN controller with command C CAN_START.
If the CAN controller receives a message from the CAN network that matches one of
the filters, the message is transmitted on the Bluetooth connection in ASCII format.
CANblue II
CAN connector
Bluetooth
connection
(SPP-Server)
CAN bus 1
PC
Bluetooth
Config
Slave
Master
Bluetooth connection
CANblue II User Manual 4.01.0126.20000 EN 3.2