Configuration as Generic PC Interface or as Bridge 20 (64)
7.3 Configuring a Bridge
Several Bluetooth devices can be connected as Master and Slave.
Use only CANblue II devices with the same firmware version for a bridge. If CANblue II
devices with new firmware version (V2.01.07 and higher) and CANblue II devices with an
older firmware version are used in a Bridge contact Ixxat support for information about
the compatibility.
Fig. 8 Configuring a bridge
To simplify the configuration, deactivate the transmission of CAN messages by the Master:
Stop the CAN controller with command C CAN_STOP or disable the transmission of CAN messages on
the connection with command C SEND_CAN_FRAMES OFF.
Make sure, that the software package and the virtual COM port are installed.
Make sure, that the virtual COM ports are installed for all devices and that the connection is
established.
Start and configure the desired configuration tool (see Configuration Tools, p. 16).
Configure the devices like an interface (see Configuring an Interface, p. 18).
Enable the autostart mode with command C AUTOSTART ON on both devices (for further
information see Autostart, p. 22).
With the desired Master device enter command D MAC_ADD <address of slave>.
Device acts as Master and connects to the Slave.
Devices start automatically.
Devices function as a Bridge between the two CAN networks.
Save the configurations on both devices with the commands C CONFIG SAVE.
CANblue II
CAN connector
Bluetooth
connection
(SPP-Server)
CAN bus 1
PC
Bluetooth
Config
Slave
Master
CANblue II
CAN connector
Bluetooth
connection
(SPP-Server)
CAN bus 2
Config
Slave
Master
Bluetooth
connection
Config connection (Bluetooth)
COM port 1 COM port 2
Only for configuration
CANblue II User Manual