Generic Mode Network and Device Communication 35 (64)
C FILTER_ENABLE
Enables a Standard filter list or a Extended filter list. Messages are forwarded if the ID is found in
the filter list. Filter lists for Standard IDs and for Extended IDs must be enabled separately.
C FILTER_ENABLE <id-typ>
Parameter
Parameter
Description
id-typ
Message type of filter entry (Standard or Extended), possible entries: STD/EXT
Example
C FILTER_ENABLE EXT
Possible Return Values
Return Value
Description
I OK: FILTER_ENABLE
Function succeeded
C FILTER_DISABLE
Disables a Standard filter list or a Extended filter list. Filter lists for Standard IDs and for Extended
IDs must be disabled separately.
C FILTER_DISABLE <id-typ>
Parameter
Parameter
Description
id-typ
Message type of filter entry (Standard or Extended), possible entries: STD/EXT
Example
C FILTER_DISABLE EXT
Possible Return Values
Return Value Description
I OK: FILTER_DISABLE
Function succeeded
CANblue II User Manual