Manual

Technical Data 12 (18)
8 Technical Data
Weight
Approx. 150 g
Operating temperature -20 °C to +70 °C
Storage temperature
-40 °C to + 85 °C
Power supply
+9 V to +36 V DC
Housing material Polyamid
CAN/CAN FD transceiver
Microchip MCP2562FD
CAN bus termination resistor 120 Ohm (only with variants with integrated bus termination resistor)
CAN bit rates
Up to 1 Mbit/s
CAN FD bit rates
500 kbit/s up to 4 Mbit/s
Protection class
IP20
Relative humidity 10 to 95 %, non-condensing
CAN-CR100
Dimensions 22.5 x 105 x 114 mm
Current consumption at 24 V Typ. 70 mA, max. 100 mA
Galvanic isolation
1 kV DC/1 sec, 500 V AC/1 min
CAN propagation delay (typical) Typ. 175 ns (35 m bus length)
CAN-CR120/HV
Dimensions 22.5 x 105 x 114 mm
Current consumption at 24 V Typ. 70 mA, max. 100 mA
Galvanic isolation
3 kV DC/1 sec, 1500 V AC/1 min
CAN propagation delay (typical) Typ. 175 ns (35 m bus length)
CAN-CR110/FO
Dimensions 22.5 x 105 x 120 mm
Current consumption at 24 V Typ. 70 mA, max. 100 mA
Galvanic isolation
1 kV DC/1 sec, 500 V AC/1 min
CAN propagation delay (typical) Typ. 300 ns (60 m bus length) between wire connection of a FO Repeater through
the fiber optic cable to the wire connection of a second FO Repeater (not including
the signal delay time of the fiber optics: approx. 5 ns/m)
FO transmitter
Broadcom HFBR 1404Z, 820 nm
FO receiver
Broadcom HFBR 2402Z, 820 nm
FO connector F-SMA connector
FO line Multi mode fiber optic cables (only glass);
Recommended: 50/125 μm, 62.5/125 μm,
also compatible with: 100/140 μm, 200 μm (consider max. line length)
Maximal line length between two
FO repeaters
50/125 μm: 1500 m
62.5/125 μm: 2000 m
CAN-CR300
Dimensions 22.5 x 105 x 114 mm
Current consumption at 24 V Typ. 90 mA, max. 125 mA
Galvanic isolation
1 kV DC/1 sec, 500 V AC/1 min
CAN propagation delay (typical) Typ. 175 ns (35 m bus length)
CAN FD Repeater User Manual
4.01.0210.20000 1.4 en-US