Product Description 6 (18)
4 Product Description
4.1 Features
CAN-CR100
• 2 x CAN/CAN FD interfaces according to ISO 11898-2
• ISO CAN FD and nonISO CAN FD
• variant with integrated bus termination resistor and variant without bus termination resistor
available
• 1 kV isolation voltage
CAN-CR120/HV
• 2 x CAN/CAN FD interfaces according to ISO 11898-2
• ISO CAN FD and nonISO CAN FD
• variant with integrated bus termination resistor and variant without bus termination resistor
available
• 3 kV isolation voltage
CAN-CR110/FO
• 2 x CAN/CAN FD interfaces:
– 1 x CAN interfaces according to ISO 11898-2
– 1 x FO interface (F-SMA connector)
• ISO CAN FD and nonISO CAN FD
• variant with integrated bus termination resistor and variant without bus termination resistor
available
• 1 kV isolation voltage
HMS Industrial Networks offers cable assemblies (F-SMA) in various lengths to connect two CAN-CR110/
FO.
CAN-CR300
• 4 x CAN/CAN FD interfaces according to ISO 11898-2
• ISO CAN FD and nonISO CAN FD
• variant with integrated bus termination resistor and variant without bus termination resistor
available
• 1 kV isolation voltage
4.2 Automatic Error Detection
The Ixxat CAN FD Repeater automatically disconnects a defective segment from the network,
allowing the remaining network to continue working. After successful troubleshooting the
segment is automatically reconnected.
A segment is detected as defect and therefore disconnected if a dominant bus level is detected
on the channel for more than 1.4 ms. If a recessive level is detected again on the channel, the
segment is reconnected automatically.