Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks of any inaccuracies or omissions. The data and illustrations found in this document are not binding. We, HMS Industrial Networks, reserve the right to modify our products in line with our policy of continuous product development. The information in this document is subject to change without notice and should not be considered as a commitment by HMS Industrial Networks.
Table of Contents 1 2 Page User Guide ........................................................................................................................... 3 1.1 Target Audience...............................................................................................................3 1.2 Related Documents ..........................................................................................................3 1.3 Document History .........................................................
10 Disposal.............................................................................................................................. 19 A Regulatory Compliance ..................................................................................................... 21 A.1 EMC Compliance (CE) ..................................................................................................... 21 A.2 FCC Compliance Statement ................................................................................
User Guide 1 3 (24) User Guide Please read the manual carefully. Make sure you fully understand the manual before using the product. 1.1 Target Audience This manual addresses trained personnel who are familiar with CAN, CAN FD and the applicable national standards. The contents of the manual must be made available to any person authorized to use or operate the product. 1.2 1.3 1.
User Guide 1.5 4 (24) Conventions Instructions and results are structured as follows: ► instruction 1 ► instruction 2 → result 1 → result 2 Lists are structured as follows: • item 1 • item 2 Bold typeface indicates interactive parts such as connectors and switches on the hardware, or menus and buttons in a graphical user interface. This font is used to indicate program code and other kinds of data input/output such as configuration scripts.
Safety Instructions 2 5 (24) Safety Instructions Risk of interference to radio and television if used in office or home environment! Use exclusively included accessories. Use exclusively shielded cables. Make sure that the shield of the interface is connected with the device plug and the plug on the other side. Malfunction caused by extension cable! According to the USB specification connect the interface directly or via an active USB hub to the computer. Do not use an extension cable. 2.1 2.
Product Description 4 6 (24) Product Description The CANbridge NT is a universal, intelligent CAN topology component, that allows the coupling of several CAN networks with different baud rates or frame formats in the operational modes Repeater/Star Coupler and Bridge. The CANbridge NT 420 additionally is capable of CAN FD. CAN messages are received by one network and transmitted in the other network, according to filter and implementation rules.
Installation 7 (24) 5 Installation 5.1 Installing the Software 5.1.1 Installing the Driver For the operation of the CAN-Gateway Configurator a VCI driver is needed. The VCI driver is constantly improved and expanded! Check if a newer version is available within the support area on www.ixxat.com. ► 5.1.2 Install the VCI driver (see Installation Guide VCI Driver).
Installation 8 (24) ► Make sure, that the cross-sectional area of the cable is equal to or larger than 0.14 mm2 resp. AWG 25. ► To remove the connector use screwdriver or similar tool. ► Connect the cables. ► Plug the connector into the housing. The shield of the CAN connector is connected to the device ground and the PE on the back of the device (DIN rail) via a 1 MΩ resistor and a 10 nF capacitor. To achieve the highest interference immunity, ground the shield of the CAN cable. 5.2.
Installation 9 (24) If a D-Sub 9 connector is used, observe the following pin allocation of the D-Sub 9 connector: Pin no. Signal — 1 2 3 4 5 6 7 CAN low CAN GND — Shield — CAN high — — 8 9 5.3 Checking and Updating the Firmware 5.3.1 Checking the Device Firmware ► Make sure, that the latest VCI driver is installed. ► Make sure, that the device is correctly connected to the host computer and to power supply.
Installation 10 (24) ► In drop down list Select device type select the device in use. ► In drop down list Select device version select V5. ► Scan for devices with button Scan Device. ► Click button Connect ► Open menu Target and select Read configuration from target. ► Save the configuration on the computer. ► Open menu Target and select Update Firmware. ► Select the update file. → and select the device in use in the combo box Target . Firmware of the connected device is updated.
Configuration 6 11 (24) Configuration The security settings set via the CAN-Gateway Configurator define if a password is needed to change the configuration. The default password is IXXAT. For more information see user manual CAN-Gateway Configurator. 6.1 Basic Configuration Malfunction caused by extension cable! According to the USB specification connect the interface directly or via an active USB hub to the computer. Do not use an extension cable. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 Fig.
Configuration 12 (24) ► Select the firmware version of the device in drop-down list Select device version (3). ► Select the desired operational mode for the device in use in drop-down list Select operational mode (4). ► Select the device in combo box Target device (11). ► Click button Connect (12) to connect the selected device. → If device is connected, STS (1) is green flashing. → Information about the target (1) device is shown.
Configuration 6.3 13 (24) Repeater/Star Coupler Configuration The CANbridge NT 200 can be configured as Repeater and the CANbridge NT 420 as Star Coupler. In the Repeater/Star Coupler mode all messages are transmitted unchanged to the other ports in Classic CAN mode. Filters, CAN-ID modifications and CAN-FD mode are not possible. 2 3 5 4 1 Fig.
Configuration 6.4 14 (24) Bridge Configuration By using the mapping table and the multiplexing table the Bridge mode allows free configuration of the transmission of CAN messages. With the CANbridge NT 420 bridging between Classic CAN and CAN FD is possible. 2 3 4 5 1 Fig. 7 Bridge configuration ► Make sure, that the basic configuration is set and that the correct device type and version are selected (see Basic Configuration, p. 11). ► Make sure, that operational mode Bridge (2) is selected.
Configuration 6.5 15 (24) Reset to Factory Settings It is possible to reset a connected device to factory settings. Fig. 8 6.6 Menu Reset to Factory Settings ► Connect the device via USB. ► Open menu Target and select Reset to Factory Settings. ► Click button Yes to confirm the reset. Read and erase LOG File In case of an error the device writes the error in a log file. The log file can be read from the device, saved as a txt file and send to the Ixxat support if needed.
Operation 7 16 (24) Operation 12 5 Fig. 9 7.1 3 4 Ports and LEDs 1 Status LED 2 Power LED 3 Mini USB port 4 CAN LEDs 1 to 4 5 User LED Mini USB Port Provided to connect the device for configuration. 7.2 Indicators 7.2.1 Power LED Indicates the status of the power supply. 7.2.
Operation 7.2.4 17 (24) CAN LED CAN 1-4 LEDs indicate the status of the corresponding CAN interface.
Technical Data 8 18 (24) Technical Data Dimensions 114.5 x 99 x 22.5 mm Weight Approx. 150 g Operating temperature -40 °C to +85 °C Storage temperature -40 °C to +85 °C Power supply 9 V to 36 V DC with overvoltage and polarity protection Current consumption Typically 110 mA (at 24 V input voltage) Housing material Polyamide Galvanic isolation 1 kV DC for 1 sec CAN transceiver (CAN 1/CAN2) SN65HVD251 CAN FD transceiver (CAN3/CAN4 withCANbridge NT 420) MCP2562FDT Max.
19 (24) Support/Return Hardware 9 Support/Return Hardware Observe the following information in the support area on www.ixxat.com: 9.1 9.2 10 • information about products • FAQ lists • installation notes • updated product versions • updates Support ► For problems or support with the product request support at www.ixxat.com/support. ► If required use support phone contacts on www.ixxat.com. Return Hardware ► Fill in the form for warranty claims and repair on www.ixxat.com.
This page intentionally left blank
Appendix A: Regulatory Compliance 21 (24) A Regulatory Compliance A.1 EMC Compliance (CE) The product is in compliance with the Electromagnetic Compatibility Directive. More information and the Declaration of Conformity is found at www.ixxat.com. A.2 FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference.
Appendix A: Regulatory Compliance A.3 22 (24) Disposal and recycling You must dispose of this product properly according to local laws and regulations. Because this product contains electronic components, it must be disposed of separately from household waste. When this product reaches its end of life, contact local authorities to learn about disposal and recycling options, or simply drop it off at your local HMS office or return it to HMS. For more information, see www.hms-networks.com.