Manual
Table Of Contents
Configuration 15 (26)
6.4 Bridge Configuration
By using the mapping table and the multiplexing table the Bridge mode allows free configuration
of the transmission of CAN messages. With the CANbridge NT 420 bridging between Classic CAN
and CAN FD is possible.
Fig. 5 Bridge configuration
► Make sure, that the basic configuration is set and that the correct device type and version
are selected (see Basic Configuration, p. 12).
► Make sure, that operational mode Bridge (1) is selected.
► In configuration tree (6) select CANbridge — General.
► If checkbox Only for specified device (4) is enabled, enter the serial number of the device to
which the configuration can be written.
► If checkbox Expert Mode (5) is enabled, select the desired settings (for more information
see User Manual CAN-Gateway Configurator).
► For the description of the CAN tunnel and of further configuration possibilities see User
Manual CAN-Gateway Configurator.
► Configure the baud rate settings for all active CAN ports and the mapping table (for more
information see User Manual CAN-Gateway Configurator on product support pages on www.
ixxat.com/support-bridges-gateways).
Only messages that are entered in the mapping table are forwarded. By default, no filter
is set and all messages are rejected.
► To write the configuration to the device, click button Write to (3).
► Click button Save or Save As (2) to save the configuration.
CANbridge NT User Manual
4.01.0331.20000 1.9 en-US