Datasheet
www.clare.com
2
LCA110
R10
Absolute Maximum Ratings
Electrical Characteristics
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Ratings Units
Blocking Voltage 350 V
P
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation
1
150 mW
Total Power Dissipation
2
800 mW
Isolation Voltage, Input to Output 3750 V
rms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1
Derate Linearly 1.33 mW/˚C
2
Derate Linearly 6.67 mW/˚C
Electrical absolute maximum ratings are at 25°C
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Current (Continuous)
AC/DC Configuration
- I
L
- - 120
mA
DC Configuration - - 200
Peak Load Current t=10ms I
LPK
- - 350 mA
On-resistance
AC/DC Configuration I
L
=120mA
R
ON
- 23 35
Ω
DC Configuration I
L
=200mA - 7 10
Off-State Leakage Current V
L
=350V I
LEAK
- - 1 µA
Switching Speeds
Turn-On
I
F
=5mA, V
L
=10V
T
ON
- - 3 ms
Turn-Off T
OFF
Output Capacitance 50V; f=1MHz C
OUT
- 25 - pF
Input Characteristics @ 25°C
Input Control Current I
L
=120mA I
F
- - 2 mA
Input Dropout Current - I
F
0.4 - - mA
Input Voltage Drop I
F
=5mA V
F
0.9 1.2 1.4 V
Reverse Input Current V
R
=5V I
R
- - 10 µA
Common Characteristics @ 25°C
Input to Output Capacitance - C
I/O
- 3 - pF