User Manual
Table Of Contents
- Introduction
- What is Ozone 7?
- Ozone 7 Standard vs. Ozone 7 Advanced
- Getting Started
- Standalone Version Operation
- Edit Menu
- Other File Menu Commands
- Saving
- Multiple File Workflow
- Playing Back Audio Files: The Transport Bar
- General Functions
- Preset System
- Migrating Presets from Ozone 5
- Module Preset System
- Standard Module Controls
- Using Multiband Modules
- Mid/Side Processing
- Equalizer
- Dynamic EQ
- Dynamics
- Exciter
- Maximizer
- Vintage Limiter
- Vintage EQ (Advanced only)
- Vintage Compressor (Advanced only)
- Vintage Tape (Advanced only)
- Master Section
- Codec Preview (Advanced only)
- Options
- General Options
- Dynamics Options
- Imager Options
- Dynamic EQ Options
- Exciter Options
- I/O Options
- App Options
- App Tab
- Tips and Shortcuts
- Automation (Plug-In Version Only)
- Shortcut Keys and Mouse Support
- Keyboard Shortcuts
- iZotope Customer Support
Preset System
OZONE 7 | PRESET SYSTEM
31
Migrating Presets from Ozone 6
Ozone 6 Preset Loading
Presets that were created in Ozone 6 can be loaded into Ozone 7. You can access your Ozone 6
presets by changing the preset manager folder path to your Ozone 6 preset folder, or by manually
copying your Ozone 6 presets into the Ozone 7 preset folder.
Changing Preset Manager file path
Open Ozone 7 and navigate to the Preset Manager. In the Preset Manager, select the “Change” button
and navigate to your Ozone 6 preset folder in the OS window that appears, select “Open” to set the
new path.
Copying Ozone 6 presets into your Ozone 7 preset folder
Navigate to your Ozone 6 preset folder (file paths listed below). Copy the presets you wish to use
within Ozone 6, navigate to the Ozone 6 preset folder and paste the presets into a folder of your
choosing.
Notes on Legacy Preset loading
Updating an Ozone 6 preset from within the Ozone 7 preset manager will update the file to work with
Ozone 7 and will not be backwards compatible.
Presets saved in the Ozone 6 Advanced component plug-ins will open in the Ozone 7 Advanced
components, with the exception of Maximizer presets that use the “Tube” mode. The “Tube” mode has
been moved in Ozone 7 from the Maximizer module to the Vintage Limiter module. This aects presets
that use the “Tube” mode of the Maximizer in Ozone 6.1 in the following ways:
• Module and component presets from Ozone 6.1 that utilized “Tube” mode of the Maximizer
cannot be loaded in Ozone 7’s Vintage Limiter module or component plug-in.
• When loading an Ozone 6.1 Global Preset that uses the Maximizer’s “Tube” mode, Ozone 7 will
replace the Maximizer module in the signal chain with the Vintage Limiter module in “Tube”
mode.
• When loading an Ozone 6.1 Project that uses the Maximizer’s “Tube” mode, Ozone 7 will replace
the Maximizer module in the signal chain with the Vintage Limiter module in “Tube” mode.
• When loading an Ozone 6.1 Maximizer module preset that uses the “Tube” mode, Ozone 7 will
display a note that reads “Invalid preset file. Please use the Vintage Limiter for Tube limiting.”
• When loading an Ozone 6.1 Maximizer component plug-in preset that uses the “Tube” mode,
Ozone 7 will display a note that reads “Invalid preset file. Please use the Vintage Limiter for
Tube limiting.”