SDS
Safety Data Sheet
According to OSHA Hazard Communication Standard, 29 CFR 1910.1200
Initial preparation date: 07.26.2018 Page 4 of 12
Threadlocker - Medium Strength - Blue
SECTION 7: Handling and storage
Precautions for safe handling:
Use only with adequate ventilation.
Avoid breathing mist or vapor.
Do not eat, drink, smoke or use personal products when handling chemical substances.
Conditions for safe storage, including any incompatibilities:
Keep container tightly sealed.
Protect from freezing and physical damage.
Store in a cool, well-ventilated area.
SECTION 8: Exposure controls/personal protection
Only those substances with limit values have been included below.
Occupational Exposure limit values:
Country (Legal Basis) Substance Identifier Permissible concentration
United States (OSHA) Powder 13463-67-7 OSHA PEL TWA 15 mg/m³ (Total
dust)
Powder 112945-52-5 OSHA PEL TWA 20.0 Million
particles per cubic foot
Liquid Additive 67-56-1 OSHA PEL TWA 200 ppm
Additive 98-82-8 OSHA PEL TWA 50 ppm, 245.0
mg/m³
Resin 80-62-6 8 hr Time Weighted Avg (TWA):
410 mg/m3
Liquid Additive 67-56-1 OSHA PEL TWA 260 mg/m³
Powder 112945-52-5 OSHA PEL TWA 0.8 mg/m³
80/(%SiO2)
WEEL Liquid Additive 57-55-6 WEEL TWA 10.0 mg/m³
Additive 80-15-9 8-Hour TWA: 6 mg/m³ (1 ppm)
NIOSH Additive 98-82-8 NIOSH REL TWA 50 ppm, 245.0
mg/m³
Powder 112945-52-5 NIOSH REL TWA 6.0 mg/m³
Resin 80-62-6 8 hr Time Weighted Avg (TWA):
410 mg/m3
Liquid Additive 67-56-1 NIOSH REL TWA 200 ppm [skin]
Liquid Additive 67-56-1 NIOSH REL TWA 260 mg/m³ [skin]
Liquid Additive 67-56-1 NIOSH REL ST 250 ppm [skin]
Liquid Additive 67-56-1 NIOSH REL ST 325 mg/m³ [skin]
Powder 13463-67-7 IDLH: 5,000 mg/m³
ACGIH Powder 13463-67-7 ACGIH TLV TWA 10 mg/m³
Liquid Additive 67-56-1 ACGIH TLV STEL 250 ppm [skin]
Additive 98-82-8 ACGIH TLV TWA 50 ppm
Liquid Additive 67-56-1 ACGIH TLV TWA 200 ppm [skin]
Biological limit values:
No biological exposure limits noted for the ingredient(s).
Information on monitoring procedures:
Monitoring of the concentration of substances in the breathing zone of workers or in the general workplace
may be required to confirm compliance with an OEL and adequacy of exposure controls.