MSDS

3
VENTILATION: Control airborne concentration below the exposure guideline. Use only with
MSDS Part #50112 Clearweld Epoxy Syringe page 3
adequate ventilation. Local exhaust ventilation may be necessary for some operations.
RESPIRATORY PROTECTION: Atmospheric levels should be maintained below the exposure
guideline. When respiratory protection is required for certain operations (e.g. spraying ), use an approved
positive pressure air supplied respirator. In confined spaces or areas with poor ventilation this is
mandatory.
SKIN PROTECTION: Use protective clothing impervious to this material. Butyl/Nitrile/neoprene gloves
should be worn. Safety shower should be located in work area. Remove contaminated clothing
immediately, wash skin area with soap and water, and launder clothing before reuse. Contaminated
leather such as shoes, belts and watchbands, should be removed and thoroughly washed before reuse. .
EYE PROTECTION: Use chemical goggles or safety glasses with side shields. If vapor exposure causes
eye irritation, use a full face air fed respirator. Eye wash fountain and emergency showers should be
located in immediate work area.
9. MATERIAL PHYSICAL ANDCHEMICAL PROPERTIES
Appearance: Pale yellow liquid with an ammoniacal odor
pH: 11.3 curative
Viscosity: circa 8000 cps ( mPa.s) @ 25
0
C, resin,and hardener
Density: 9.4 pounds per gallon @ 25
0
C resin,
Vapor Pressure: <0.05 mmHg @ 25
0
C
Vapor Density: n/d
Boiling Point: > 212 °F, (>100 °C) Hardener
Flash Point: > 93,3°C (> 200 °F) resin,> 285
0
F (> 140 °C) Hardener
10. REACTIVITY AND STABILITY
Hazardous polymerization is very unlikely to occur. Materials such as oxidizing agents and isocyanates
and polyurethanes should be avoided as these will cause exothermic polymerization. Avoid extreme heat.
Fire, pyrolysis and thermal decomposition will produce noxious gases such as CO, CO
2
, NOx, amines,
ammonia and others. The material is designed as an accelerator curing agent for epoxy resins and will
react with them to give a hard glassy polymer with the evolution of heat.
11. TOXICOLOGY
This toxicity data is based on a very similar product chemically.
Acute Oral LD50 1670 mg/kg rat
Acute Inhalation LC50 no data on product itself
Acute Dermal LD50 1240 mg/kg rabbit
Dermal Irritation irritating corrosive rabbit
Eye Irritation irritating corrosive rabbit
Sensitization some sensitizing potential Guinea Pig
Carcinogens This product does not contain any substances that are considered by OSHA,
NTP, IARC or ACGIH to be probable or suspect human carcinogens
Mutagens Results in vitro have been negative
12. ECOLOGY