SDS
Legend:
– Data either not available or does not fill the criteria for classification
– Data available to make classification
Reactivity
See section 7
Chemical stability
Product is considered stable and hazardous polymerisation will not occur.
Possibility of hazardous
reactions
See section 7
Conditions to avoid
See section 7
Incompatible materials
See section 7
Hazardous decomposition
products
See section 5
SECTION 11 Toxicological information
Information on toxicological effects
Inhaled
The material can cause respiratory irritation in some persons. The body's response to such irritation can cause further lung damage.
Ingestion
The material has
NOT
been classified by EC Directives or other classification systems as "harmful by ingestion". This is because of the lack of
corroborating animal or human evidence.
Skin Contact
This material can cause inflammation of the skin on contact in some persons.
The material may accentuate any pre-existing dermatitis condition
Skin contact is not thought to have harmful health effects (as classified under EC Directives); the material may still produce health damage
following entry through wounds, lesions or abrasions.
Open cuts, abraded or irritated skin should not be exposed to this material
Entry into the blood-stream, through, for example, cuts, abrasions or lesions, may produce systemic injury with harmful effects. Examine the skin
prior to the use of the material and ensure that any external damage is suitably protected.
Eye
This material can cause eye irritation and damage in some persons.
Chronic
Long-term exposure to respiratory irritants may result in airways disease, involving difficulty breathing and related whole-body problems.
Skin contact with the material is more likely to cause a sensitisation reaction in some persons compared to the general population.
Substance accumulation, in the human body, may occur and may cause some concern following repeated or long-term occupational exposure.
ClearWeld Part A, Resin
TOXICITY
IRRITATION
Not Available
Not Available
bisphenol A diglycidyl ether
polymer
TOXICITY
IRRITATION
dermal (rat) LD50: >1200 mg/kg
[2]
Not Available
Oral (Mouse) LD50; >500 mg/kg
[2]
4-tert-butylphenyl glycidyl
ether
TOXICITY
IRRITATION
dermal (rat) LD50: >2000 mg/kg
[1]
Not Available
Oral (Rat) LD50; >2000 mg/kg
[1]
Legend:
1. Value obtained from Europe ECHA Registered Substances - Acute toxicity 2. Value obtained from manufacturer's SDS. Unless otherwise
specified data extracted from RTECS - Register of Toxic Effect of chemical Substances
ClearWeld Part A, Resin
Asthma-like symptoms may continue for months or even years after exposure to the material ends. This may be due to a non-allergic condition
known as reactive airways dysfunction syndrome (RADS) which can occur after exposure to high levels of highly irritating compound.
The following information refers to contact allergens as a group and may not be specific to this product.
Contact allergies quickly manifest themselves as contact eczema, more rarely as urticaria or Quincke's oedema.
Acute Toxicity
Carcinogenicity
Skin Irritation/Corrosion
Reproductivity
Serious Eye Damage/Irritation
STOT - Single Exposure
Respiratory or Skin
sensitisation
STOT - Repeated Exposure
Mutagenicity
Aspiration Hazard
SECTION 12 Ecological information
Toxicity
ClearWeld Part A, Resin
Endpoint
Test Duration (hr)
Species
Value
Source
Not
Available
Not Available
Not Available
Not
Available
Not
Available
Version No:
1.1
Page
5
of
8
ClearWeld Part A, Resin
Issue Date:
10/07/2022
Print Date:
10/07/2022
Continued...