SDS

Source
Ingredient
Material name
TWA
STEL
Peak
Notes
Ingredient
TEEL-1
TEEL-2
TEEL-3
Ingredient
Original IDLH
Revised IDLH
Ingredient
Occupational Exposure Band Rating
Occupational Exposure Band Limit
Notes:
Occupational exposure banding is a process of assigning chemicals into specific categories or bands based on a chemical's potency and the
adverse health outcomes associated with exposure. The output of this process is an occupational exposure band (OEB), which corresponds to a
range of exposure concentrations that are expected to protect worker health.
US OSHA Permissible Exposure
Limits (PELs) Table Z-1
silica amorphous
Particulates Not Otherwise
Regulated (PNOR)- Respirable
fraction
5 mg/m3
Not
Available
Not Available
Not
Available
US OSHA Permissible Exposure
Limits (PELs) Table Z-1
silica amorphous
Particulates Not Otherwise
Regulated (PNOR)- Total dust
15 mg/m3
Not
Available
Not Available
Not
Available
US OSHA Permissible Exposure
Limits (PELs) Table Z-3
silica amorphous
Amorphous, including natural
diatomaceous earth
80 (%SiO2)
mg/m3 / 20
mppcf
Not
Available
Not Available
Not
Available
US NIOSH Recommended
Exposure Limits (RELs)
silica amorphous
Silica, amorphous
6 mg/m3
Not
Available
Not Available
Not
Available
Emergency Limits
4,4'-diphenylmethane
diisocyanate (MDI)
0.45 mg/m3
Not Available
Not Available
4,4'-diphenylmethane
diisocyanate (MDI)
29 mg/m3
40 mg/m3
240 mg/m3
zeolites
30 mg/m3
330 mg/m3
2,000 mg/m3
zeolites
30 mg/m3
330 mg/m3
2,000 mg/m3
silica amorphous
18 mg/m3
200 mg/m3
1,200 mg/m3
silica amorphous
18 mg/m3
100 mg/m3
630 mg/m3
silica amorphous
120 mg/m3
1,300 mg/m3
7,900 mg/m3
silica amorphous
45 mg/m3
500 mg/m3
3,000 mg/m3
silica amorphous
18 mg/m3
740 mg/m3
4,500 mg/m3
propylene carbonate
34 mg/m3
370 mg/m3
2,200 mg/m3
4,4'-diphenylmethane
diisocyanate (MDI)
75 mg/m3
Not Available
MDI, propoxylated
Not Available
Not Available
MDI homopolymer
Not Available
Not Available
zeolites
Not Available
Not Available
Talc
1,000 mg/m3
Not Available
MDI, propylene glycol,
trimethylolpropane,triether
Not Available
Not Available
silica amorphous
3,000 mg/m3
Not Available
propylene carbonate
Not Available
Not Available
Occupational Exposure Banding
MDI, propoxylated
E
≤ 0.1 ppm
MDI homopolymer
E
≤ 0.1 ppm
MDI, propylene glycol,
trimethylolpropane,triether
E
≤ 0.01 mg/m³
propylene carbonate
E
≤ 0.1 ppm
Exposure controls
Appropriate engineering
controls
All processes in which isocyanates are used should be enclosed wherever possible.
Total enclosure, accompanied by good general ventilation, should be used to keep atmospheric concentrations below the relevant exposure
standards.
If total enclosure of the process is not feasible, local exhaust ventilation may be necessary.
Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Well-designed engineering controls can
be highly effective in protecting workers and will typically be independent of worker interactions to provide this high level of protection.
The basic types of engineering controls are:
Process controls which involve changing the way a job activity or process is done to reduce the risk.
Individual protection
measures, such as personal
protective equipment
Eye and face protection
Safety glasses with side shields.
Chemical goggles. [AS/NZS 1337.1, EN166 or national equivalent]
Contact lenses may pose a special hazard; soft contact lenses may absorb and concentrate irritants.
Skin protection
See Hand protection below
Version No:
11.16
Page
6
of
14
PlasticBonderSyringe Black - Part A
Issue Date:
12/07/2023
Print Date:
12/07/2023
Continued...