Installation Manual User guide
J.P.Instruments
Fuel Flow Installation Manual  
 Report # 503 
for EGT-701 with Fuel Flow Option   Page 7 of 14 
    Rev B : Date 03/14/97
9… Pilot Programmable Modes: (
excerpt from STC 2586NM)
See JPI Installation Manual For EGT-701, No 103 Page 8 for more information. 
RS232/422 Input Ports (EGT-701(),with Fuel Flow option Only!: 
Single Line Receive Method:  RS-232C, RS423, or 5 Volt Serial. 
Dual Line Receive Method:  RS-422 or RS-485. 
Protocol:  1 Start bit, 8 Data bits, 1 Stop bit. 
Baud Rate:  L 1 = 9600, L 2 = 1200 
Format:  Moving Map Output: L 1 = King KIN-88, L 2 = Northstar 
RS232 Output Port 
Transmit Method:  RS-232 Single Line. 
Protocol:  1 Start bit, 8 Data bits, 1 Stop bit. 
Baud Rate:  9600 
Transmit Format:  King KIN-88. 
Fuel Flow Transducer, Standard (FXT-201)  Fuel Flow Transducer, Gravity Only (FXT-231): 
Range:  0.6 to 60 GPH  Range:      3 to 90 GPH 
Linearity:  %1 (8 to 60 GPH)  Linearity:   %1 (8 to 60 GPH) 
K Factor  Approx. 29,000  K Factor:    Approx. 19500 
Pressure Drop:  1.2 PSI at 30 GPH 
4.8 PSI at 60 GPH 
Pressure Drop:    .31 PSI at 30 GPH 
2.8 PSI at 90 GPH 
Working Press:  200 PSI  Working Press:  200 PSI 
Min. Burst Press: 2000 PSI  Min. Burst Press: 2000 PSI 
Temp. Range: -65'C to 125'C  Temp. Range: -65'C to 125'C 
Fuel Ports: 1/4" Female NPT  Fuel Ports: 1/4" Female NPT 